Makita G7301R Bedienungshandbuch

Stöbern Sie online oder laden Sie Bedienungshandbuch nach Stromgeneratoren Makita G7301R herunter. Makita G7301R Owner`s manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - GÉNÉRATEUR

3ZZ9990180GENERATORINSTRUCTIONS FOR USEISSUE EMD-GU1539PRINTED IN JAPANMakita Corporation3-11-8, Sumiyoshi-choAnjo, Aichi 446-8502 Japan3ZZ9020107GENE

Seite 2

3. COMPONENTS−4−TANK CAPFUEL STRAINER(FUEL COCK)CHOKE LEVERSPARK PLUGCAPMUFFLERCOVERRECOIL STARTEREARTH(GROUND)TERMINALEXHAUSTOUTLETOIL GAUGE (OIL FIL

Seite 3

−5−ENGLISHHOUR METERPILOT LAMPFULL POWERSWITCHVOLTMETERAC RECEPTACLEKEY SWITCH(Electric starter model)IDEL CONTROLSWITCHENGINE SWITCH(Recoil starter m

Seite 4

4. PRE-OPERATION CHECKS−6−UPPER LEVELLOWERLEVELOIL FILLER NECKOIL GAUGE(OIL FILLER)UPPER LEVELLOWER LEVELCHECK ENGINE OIL.Before checking or refilling

Seite 5 - [CAUTION]

−7−ENGLISH Check fuel level at fuel level gauge. If fuel level is low, refill with automotiveunleaded gasoline only.This engine is certified to operat

Seite 6 - CONTENTS

−8−BATTERY INSTALLTIONRecommended Battery: A capacity of 12V-24AH or larger.Death, personal injury and/or property damage may occur unlessinstructions

Seite 7 - 1. SAFETY PRECAUTIONS

−9−ENGLISHBATTERY BASEBATTERY FRAMEBATTERYBOLTBATTERY RETAINERNUTM8 NUTSPRINGWASHERM8 BOLT andWASHERBATTERYCABLE (-)BATTERYCABLE (+)SIDE PLATEAAM8 BOL

Seite 8

−10−GROUNDING THE GENERATOR To ground the generator to the earth,connect the grounding lug of thegenerator to the grounding spikedriven into the earth

Seite 9 - 2. SPECIFICATIONS

5. OPERATING PROCEDURES−11−ENGLISH(a) Turn the engine switch to the position"ON". (Recoil starter model only)(b) Turn the AC circuit breaker

Seite 10 - 3. COMPONENTS

−12−(f)[Electric starter model]Insert the key into the key switch andturn it clockwise to the "RUN" positionto start the engine.Then turn th

Seite 11 - CONTROL PANEL

−13−ENGLISHUSING ELECTRIC POWER Make sure that the appliance is switched OFF before connecting it tothe generator. Do not move the generator while it

Seite 12 - 4. PRE-OPERATION CHECKS

ENGLISHFEDERAL EMISSIONS COMPONENT DEFECT WARRANTYEMISSIONS COMPONENT DEFECT WARRANTY COVERAGE - This emission warranty isapplicable in all States, ex

Seite 13 - CHECK ENGINE FUEL

−14−(c) Insert the plug (s) of the electricalappliance(s) into the receptacle. Check the amperage of thereceptacles used referring to TABLE1, and be s

Seite 14 - BATTERY INSTALLTION

−15−ENGLISHTABLE 1NOTE :When the AC circuit breaker turns off during operation, the generator is overloaded or the appliance is defective. Stop the ge

Seite 15

−16−FULL POWER SWITCHSelect the voltage using the FULLPOWER SWITCH in accordance with theelectrical appliance. Refer to TABLE 2.120V 120V 240V Change

Seite 16 - EARTH TERMINAL

−17−ENGLISH(2) CONNECTING TO DOMESTIC CIRCUITS (HOUSE WIRING)This generator is neutral grounded type.If a generator is to be connected to residential

Seite 17 - 5. OPERATING PROCEDURES

−18−Utility high lineMeter boxGeneratorHouse circuit breakerXWYX(X)(Y)(G)(W)WYTransferswitch240V4P- Receptacle120Vappliance120Vappliance240Vappliance(

Seite 18 - CHOKE LEVER

−19−ENGLISH(3) DC APPLICATIONThe DC terminal is used only for charging12 volt batteries. It provides up to 12V-8.3A (100W) of maximum power.CONNECTION

Seite 19 - USING ELECTRIC POWER

−20−OPENCLOSECLOSEOIL SENSORDo not remove OIL SENSORPROBE when refilling with oil. Remove oil filler cap on theopposite side of carburetor.[CAUTION]ST

Seite 20 - PILOT LAMP

(1) HOW TO USE IDLE CONTROL Start the engine with IDLE CONTROLSWITCH off.NOTE :Warm up the engine without a load for afew minutes. Turn IDLE CONTROL S

Seite 21 - Receptacle, duplex

6. WATTAGE INFORMATION−22−Some appliances need a "surge" of energy when starting. This means that the amount of electrical power needed to s

Seite 22 - 120V 120V

−23−ENGLISHVOLTAGE DROP IN ELECTRIC EXTENSION CORDSWhen a long electric extension cord is used to connect an appliance or tool to thegenerator, a cert

Seite 23

*The replacement parts used for required maintenance services.*Consequential damages such as loss of time, inconvenience, loss of use of the engineore

Seite 24

7. SPARK ARRESTER−24−SPARK ARRESTERIn a dry or wooded area, it is recommendable to use the product with a spark arrester.Some areas require the use of

Seite 25

8. MAINTENANCE SCHEDULE−25−ENGLISHDAILY INSPECTIONBefore running the generator, check the following service items:Excessive vibration,noiseClean air c

Seite 26 - OIL SENSOR

−26−*Note: 1. Initial oil change should be performed after first twenty (20) hours ofoperation. Thereafter change oil every hundred (100) hours. Befor

Seite 27 - IDLE CONTROL

9. "HOW-TO" MAINTENANCE−27−ENGLISHENGINE OIL CHANGE Change engine oil every 100 hours.(For new engine, change oil after 20hours.)(a) Drain o

Seite 28 - 6. WATTAGE INFORMATION

−28−CLEANING AND ADJUSTINGSPARK PLUG(a) If the plug is contaminated withcarbon, remove it using a plug cleaneror wire brush.(b) Check electrode gap.Ad

Seite 29 - Resistance

−29−ENGLISHCHECKING CARBON BRUSH If the brush become excessively worn, itscontact pressure with the slip ringchanges and causes a roughened surfaceon

Seite 30 - 7. SPARK ARRESTER

10. PREPARATION FOR STORAGE−30−The following procedures should be followed prior to storage of your generator forperiods of 6 months or longer. Drain

Seite 31 - 8. MAINTENANCE SCHEDULE

11. TROUBLESHOOTING−31−ENGLISHWhen generator engine fails to start after several attempts, or if no electricity isavailable at the output socket, chec

Seite 32 - (Yearly)

12. WIRING DIAGRAM−32−Wiring color cordBlk BlackBrn/WBrown/White R RedBlk/W Black/WhiteGrnGreen W WhiteBlu BlueGrn/WGreen/WhiteYYellowLBlu Light blueO

Seite 33 - Oil capacity : 1.2 liters

−33−ENGLISHGENERATORCONTROL BOXENGINEFull powerswitch120/240VSolenoidFuel cutsolenoid120VBrn120VBluWGrnYGryBlkGrnGrnGrn/WGrn/WGrnSCBrnWRMC2BrushBluBlk

Seite 34 - 0.7 to 0.8 mm

ENGLISHFACTORY SERVICE CENTERS IN CANADABRITISH COLUMBIARICHMOND (Vancouver Regional Office)11771 Hammersmith Way, Richmond, V7A.5H6Tel. 1.800.663.090

Seite 35 - CHECKING CARBON BRUSH

13. OPTIONAL PARTS−34−HANDLE GUIDEM8 BOLT and WASHERM8 BOLT and WASHERHANDLE (R)HANDLE (L)WHEEL SHAFTHANDLEBRACKETBRACKETM8 NUTM8 NUTROOF PIPEWHEELWAS

Seite 36 - 10. PREPARATION FOR STORAGE

G7300取説_GU2043 05.1.26 11:27 AM ページ35

Seite 37 - 11. TROUBLESHOOTING

Makita Corporation3-11-8, Sumiyoshi-choAnjo, Aichi 446-8502 JapanISSUE EMD-GU2043PRINTED IN JAPANJanuary 2005 CE-SKG7300取説_GU2043 05.1.26 11:27 AM

Seite 38 - 12. WIRING DIAGRAM

ENGLISHFOREWORDThank you for purchasing a Makita generator.This manual covers operation and maintenance of the Makita generators.All information in th

Seite 39 - CONTROL BOX

CONTENTS1. SAFETY PRECAUTIONS・・・・・・・・・・・・・・・・・・・・・・12. SPECIFICATIONS・・・・・・・・・・・・・・・・・・・・・・・・・・33. COMPONENTS・・・・・・・・・・・・・・・・・・・・・・・・・・・44. PRE-OPERAT

Seite 40 - 13. OPTIONAL PARTS

1. SAFETY PRECAUTIONS−1−ENGLISHPlease make sure you review each precaution carefully.Do not operate the generator near gasoline or gaseous fuel becaus

Seite 41

−2−Do not contact the generator to a commercial power line. Connection to a commercialpower line may short circuit the generator and ruin it or cause

Seite 42 - Makita Corporation

2. SPECIFICATIONS−3−ENGLISHMODELTypeStarting systemLmmmmmmmLkW / rpmLkgModelTypeVARated output AC Output Rated voltageFuel tank capacityEngine oil cap

Kommentare zu diesen Handbüchern

Keine Kommentare